Discover the advanced MONITOR DEFIBRILLATOR, seamlessly blending cutting-edge technology with reliability. Exclusively available at EUSTAR & GOLD, your trusted provider of high-quality medical equipment and supplies, this device ensures precise monitoring and rapid response in critical situations. Sourced from leading manufacturers, our equipment guarantees top performance at competitive prices. Elevate your medical practice with the assurance and excellence that define EUSTAR & GOLD.
This is a biphasic defibrillator machine.
FEATURES:
BATTERY-LEVEL INDICATOR:
- real-time view of monitor of battery lifeINTERNAL THERMAL PRINTER:
- 50MM Integrated Thermal RecorderPADDLES:
- Charging &shocking can be easily operated through according buttons
- Quickly can be converted from adult to pediatric by removing the outer surfaceBIPHASIC TECHNOLOGY:
- With impedance compensation for more effective, less energy and reduced hurt to the heartDATA STORAGE:
- 65 hours of all measured parameters
SPECIFICATIONS
- TYPE WI
- PULSE TYPE Rectangular, constant current
- PULSE AMPLITUDE 0-180 mA+ 10% or 5 mA (whichever is greater)
- PACING RATE Variable from 3pm to 180ppm ±1.5% (increments or decrements by a value of 2ppm
- MULTI-FUNCTION ELECTRODE (MPE) PADS Multi-purpose defibrillation/pacing electrodes
- PAUSE Pacing pulse frequency reduced by a factor of 4 when activated
- REFRACTORY PERIOD NC (WI demand do not have this specification)
- PULSE WIDTH 20+ 1.5ms
- OUTPUT PROTECTION fully defibrillator protected and isolated
SPO2 Module:
- MEASUREMENT RANGE 30-100%, ±2% between 80%-90%, others ±5%
- ALARM RANGE User set high limit and low limit
- ALARM ACCURACY ±10 within setting values
- ALARM TIME ACCURACY Less than 12 sec.
MB_ETCO2:
- TYPE OF SENSOR By-pass RANGE 0-19.7% (0-150mmHg, or 0-20kPa)
- TECHNICAL PRINCIPLE Non-dispersive infrared gas analysis NDIR RESOLUTION0.1 mmHg
- STORAGE CONDITION -40°C to 70°C, <90%RH, non-condensing ACCURACY 0-40mmHg ±2 mmHg 41-70 mmHg ± 5% of reading 71-100 mmHg ± 8% of reading 101-150mmHg ± 10% of reading
- OPERATING CONDITIONS -5°C to 50°C,10 to 90%RH, non-condensing ACCURACY0-40 mmHg ±2 mmHg 41-70 mmHg ± 5% of reading 71-100 mmHg ± 8% of reading101-150 mmHg ± 10% of reading
- AMBIENT PRESSURE 55-115kPa ACCURACY 0-40 mmHg ±2 mmHg 41-70 mmHg ± 5% of reading 71-100 mmHg ± 8% of reading 101-150 mmHg ± 10% of reading
- POWER SUPPLY 5V+5% (max ripple 200 mVp-p) RESPIRATORY RATE* 2-150 BPM
- TDP Typical value 120mA Excursion calibration typical value 280mA RR* MEASUREMENT ACCURACY 1%+ BPM
MB_NIBP:
- MEASUREMENT UNIT mmHg/kPa AMBIENT PRESSURE 55-115kPa
- MEASUREMENT RANGE Adult: 10-270mmHg/kPa Pediatric: 10-200mmHg/kPaNeonatal: 10- 135mmHg/kPa POWER SUPPLY 5V + 5% (max ripple 200 mVp-p) TDPTypical value 120mA Excursion calibration typical value 280mA
- RESOLUTION 1 mmHg RANGE 0-19.7% (0-150mmHg, or 0-20kPa)
- Maximum mean error: 5mmHg Maximum standard deviation: 8mmHg
RESOLUTION 0.1 mmHg
- TYPE OF SENSOR By-pass ACCURACY 0.1mmHg 0-40 mmHg ±2 mmHg 41-70 mmHg ±5% of reading 71-100 mmHg ±8% of reading 101-150mmHg +10% of reading
- TECHNICAL PRINCIPLE Non-dispersive infrared gas analysis NDIR ACCURACY 0.1 mmHg 0-40 mmHg ±2 mmHg 41-70 mmHg ±5% of reading 71-100 mmHg ±8% of reading101-150mmHg +10% of reading
- STORAGE CONDITION -40°C to 70°C, <90%RH, non-condensing RESPIRATORYRATE* 2-150 BPM 1%+ BPM
- OPERATING CONDITIONS 5°C to 50°C, 10 to 90% RH, non-RR* MEASUREMENTcondensing ACCURACY